Tuesday, November 30, 2010

Ballymore Eustace Changes to On-Site Electro-Chlorination (OSEC)

Ballymore Eustace Water Treatment Plant supplies 70% of Dublin’s water and is currently being expanded from 250 Ml/d to 318 Ml/d, with a planned peak capacity of 400 Ml/d. Siemens Water Technologies have provided two OSEC systems each be capable of producing 1,000 kg/d of chlorine to replace the use of chlorine gas for chlorination. Both units will operate in tandem producing 24 hours’ worth of chemical during the 8 hour low-tariff energy period.
Siemens electrolyzer unit where brine is
turned into sodium hypochlorite


Water softened to <17 mg/L hardness is used to produce a 2.8% w/w brine solution from stored salt. The brine solution is passed through an electrolyzer (image right) where a current is passed between two electrodes resulting in chlorine gas being produced at the positive electrode (anode) and sodium hydroxide and hydrogen gas at the negative electrode (cathode). The chlorine then reacts with the sodium hydroxide to produce a 0.8% sodium hypochlorite  solution which is stored before added to the finished water for disinfection. Salt usage equates to 3.0-3.5 kg per kg chlorine equivalent. Fifty-seven liters of 0.8% sodium hypochlorite is equivalent to 0.45 kgs of chlorine gas or 3.79 liters of commercial sodium hypochlorite (12%). This results in a much safer and cost effective chlorination system.  Further information on Siemens OSEC technology.

Monday, November 29, 2010

Septic Tank Design in the United States

My undergraduates are looking at small scale treatment systems this week and here is a very interesting video looking at the design of  aUS septic tank system which gives us an interesting comparison with our own systems here in Ireland.

Sunday, November 28, 2010

Leakage Remains a Challenge for Suppliers

Leakage is the starting point in the conservation of drinking water supplies. In the UK leakage reduction targets are monitored by the Water Services Regulation Authority (Ofwat). However a number of companies have failed their targets for 2009/10 including Yorkshire Water who lost on average 295 million litres a day (ML/d) over this period. The target for 2009/10 was set at 3,275 ML/d for all companies in England and Wales and this was almost achieved with reported loss for the period of 3,280 ML/d. However, the overall trend is still downwards with 8.4 and 34.2% reductions since 2005/6 and 1995/6 respectively. Thames Water still are losing the most via leakage at 670 ML/d with Severn and Trent Water close behind at 495 ML/d, but both within their targets of 685 and 500 ML/d respectively. Where targets are not meet then Ofwat can force companies to invest even more money in achieving leakage reduction. For more information about company leakage and performance in general see Ofwat’s annual report: Service and delivery – performance of the water companies in England and Wales 2009-10: Water today, water tomorrow.

Friday, November 26, 2010

Undergraduates at Leixlip WWTP

We were very lucky to be shown around Leixlp Wastewater Treatment Plant just before it snowed. Our thanks to Tom Sexton and Kildare County Council for making us so welcome.



Tom Sexton explains the odour control system at Leixlip



Outer casing of sludge centrifuge


Rare chance to see inside a
sludge centrifuge
 

Thursday, November 25, 2010

Asbestos Exposure? Act Now!

The risk from asbestos in drinking water is still under debate, but for all of us in the water industry asbestos is all around us and it is inevitable that many of us will have been exposed to airborne asbestos at some time, especially in the past when awareness was not so acute. MesotheliomaSymptoms.com is an extensive database of information and resources to better understand the symptoms of mesothelioma, as well as asbestosis, and the various aspects of diagnosis, prognosis, treatment, and many other factors of survival.  Symptoms of mesothelioma usually do not appear for 20 to 50 years after asbestos exposure, however those who think they may have been exposed should check out the website.

Wednesday, November 24, 2010

CDP Water Disclosure 2010 Global Report


The Carbon Disclosure Project (CDP) is an independent not-for-profit organization that collates greenhouse gas emissions and climate change strategies of the world’s leading corporate bodies.  They have just published the CDP Water Disclosure 2010 Global Report on line in which water use by leading corporate bodies is listed and explored.

Tuesday, November 23, 2010

Inspecting Septic Tanks

New regulations coming into place next year will require all septic tank systems in Ireland to be inspected.  Here is a interesting video from the US looking at some problems associated with tank assessment.